ClampingBeta
Clamping Planning Card
Printable engineering card for friction-based clamp force calculation, reaction planning, and operation sequence.
Inputs
Results
Effective lateral force used in calculation245.3 N
Required total clamp force1.96 kN
Required force per clamp0.98 kN
Applied formula
F_req = (F_lat x SF) / μ
F_req = (245.3 x 1.60) / 0.20
Machining direction note
-
Warnings
No critical warning. Still validate force path and deformation risk.
Clamping Points Table
Clamping Sequence
Checklist
Completed items: 0/6
Notes Table
References
- Base friction equation: Freq = (F_lat x SF) / μ.
- When μ is low, mechanical stops are safer than friction-only retention.
- Short and rigid force paths improve repeatability.
- Use spread contact pads on thin-wall regions.
Disclaimer
Typical guidance, verify with standards and responsible engineer.